PN2571
Pressure sensor with display
PN-250-SEG14-MFRKG/US/ /V
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — PN2571-02 — 01.03.2024 —
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analog signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / closed; (configurable)
Max. voltage drop switching
output DC
[V]
2
Permanent current rating of
switching output DC
[mA]
250
Switching frequency DC [Hz]
< 500
Number of analog outputs
1
Analog current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analog voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit
protection
yes (non-latching)
Overload protection
yes
Measuring/setting range
Measuring range 0...250 bar 0...3625 psi 0...25 MPa
Analog start point 0...200 bar 0...2900 psi 0...20 MPa
Analog end point 50...250 bar 725...3625 psi 5...25 MPa
Factory setting / CMPT = 2
Set point SP 1.5...250 bar 25...3625 psi 0.15...25 MPa
Reset point rP 0.5...249 bar 10...3610 psi 0.05...24.9 MPa
Min. difference between SP
and rP
1.5 bar 15 psi 0.15 MPa
In steps of 0.5 bar 5 psi 0.05 MPa
Status_B High Resolution / CMPT = 3
Set point SP 1.6...250 bar 23...3626 psi 0.16...25 MPa
Reset point rP 0.5...249 bar 8...3611 psi 0.05...24.9 MPa
Min. difference between SP
and rP
1.1 bar 15 psi 0.11 MPa
In steps of 0.1 bar 1 psi 0.01 MPa
Accuracy / deviations
Switch point accuracy
[% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL
= Best Fit Straight Line; LS = limit value setting)